[2025-08-13 10:49:57]
Tr00pz - Posts: 24
There's a few ways to do this. You need to set 'Line Stop Time' to the same as the end time so that it will only display the range bars within the opening range. First image shows it on 5-minute bars (or other bar periods that start a new bar on the 30-minute; 1/2/3/5/10/15). If you want just a single bar displayed for each day then you would need to use a bar period that is equal to the opening range.

Alternatively, you could have an intraday chart with evening session disabled and set session start time to 9:30:00 and session end time to 09:59:59 with the bar period set to 30-minutes. This would display the bars side by side for each day so you can compare between days easier.
Date Time Of Last Edit: 2025-08-13 10:50:57
image2025-08-13 06 36 03.jpg / V - Attached On 2025-08-13 10:50:16 UTC - Size: 482.88 KB - 36 views